Flow Details
π Flow:
-
Trigger:
- Executes every 1 minute to analyze water flow and leakage data.
-
Condition:
- Monitors the water flow from "Watermeter - Current usage".
- Tracks the time:
- With flow (leakage detection).
- Without flow (to detect extended periods of no activity).
-
Actions:
β If flow > 0:- Resets the "no flow" timer.
- Increases the percentage time with flow, up to a maximum of 100%.
π If flow = 0:
- Tracks time with no flow.
- Checks for periods of 2 hours with no flow to reset micro-leak tracking.
β οΈ Leak Detection:
- If no 2-hour flowless period is detected within 24 hours, sets leakage to 100%.
-
AWTRIX3 Updates:
- Sends real-time water flow (liters/min) and leakage percentage to AWTRIX3 via the "AWTRIX3 - Send Custom App" device.
-
Logging:
- Provides detailed logs of flow status, time with/without flow, and leakage percentage.
More information:
Domoticz: www.domoticz.com
Domoticz AWTRIX3 Plugin: https://github.com/galadril/Domoticz-AWTRIX3-Plugin
local FLOW_DEVICE = 'Watermeter - Current usage' -- Flow device
local LEAK_DEVICE = 'Watermeter - Leakage percent' -- Percent dummy device
return {
active = true,
-- Trigger section: run the script every 1 minute
on = {
timer = {
'every 1 minutes'
}
},
-- Custom logging level for this script
logging = {
level = domoticz.LOG_INFO,
marker = "AWTRIX_LEAK"
},
data = {
time_0_flow = { initial = 0 },
total_time = { initial = 0 },
currentIndex = { initial = 0 }
},
execute = function(domoticz)
-- Flow in liters/minute
local flow = tonumber(domoticz.devices(FLOW_DEVICE).rawData[1])
-- Dummy device in %
local leakage = domoticz.devices(LEAK_DEVICE)
local time_with_flow = tonumber(leakage.rawData[1])
local new_time_with_flow = time_with_flow
-- 1 / Leakage "open valve"
if (flow > 0) then
domoticz.data.time_0_flow = 0 -- There is flow
new_time_with_flow = new_time_with_flow + 1 -- Time with flow
if (new_time_with_flow > 100) then
new_time_with_flow = 100
end
else
new_time_with_flow = 0
domoticz.data.time_0_flow = domoticz.data.time_0_flow + 1 -- Time without flow
end
-- 2 / Micro continuous flow (drip)
domoticz.data.total_time = domoticz.data.total_time + 1 -- Time without since last 2 hours with no flow
if (domoticz.data.time_0_flow > 120) then
-- 2 hours with no flow
domoticz.data.total_time = 0
elseif (domoticz.data.total_time > (60 * 24)) then
-- 24 hours since last 2 hours with no flow
new_time_with_flow = 100
end
-- Log
domoticz.log(new_time_with_flow .. ' minutes with flow')
domoticz.log(domoticz.data.time_0_flow .. ' minutes without flow')
domoticz.log(domoticz.data.total_time .. ' minutes without 2hrs without flow')
-- Update dummy device %
if (time_with_flow ~= new_time_with_flow) then
leakage.update(0, new_time_with_flow)
end
-- Description for AWTRIX3
local flowStatus = string.format("%.1f L/min", flow)
local leakStatus = string.format("%d%%", new_time_with_flow)
-- Create individual JSON entries for flow and leak
local statuses = {
{ app = 'Water1', text = flowStatus, icon = 18191 }, -- Flow status with its icon
{ app = 'Water2', text = leakStatus, icon = 59365 } -- Leak status with its icon
}
-- Send to AWTRIX3
local appDevice = domoticz.devices('AWTRIX3 - Send Custom App')
if appDevice then
local statusesJSON = domoticz.utils.toJSON(statuses)
domoticz.log("Sending data to AWTRIX: " .. statusesJSON, domoticz.LOG_INFO)
appDevice.setDescription(statusesJSON)
appDevice.switchOn().afterSec(2)
else
domoticz.log("AWTRIX3 - Send Custom App device not found", domoticz.LOG_ERROR)
end
end
}